Imagen | Descripción | Solicitar Oferta | |
---|---|---|---|
Variadores SINAMICS G120X IP20 3C2, sin filtro de red, con IOP-2 | |||
0.75 kW | |||
![]() |
6SL3220-3YC10-0UB0
SINAMICS G120X Potencia asignada: 0,75 kW al 110% 60 s, 100% 240 s sin filtrar 200-240 V 3 AC + 10/– 20 %, 47-63 Hz Temperatura ambiente –20 a +45 °C Tamaño: FSA Grado de protección IP20/UL open Type pintura 3C2 Con Intelligent Operator Panel Sin ampliación de IO Bus de campo integrado: MODBUS RTU, BACnet MS/TP,USS |
||
![]() |
6SL3220-3YC10-0UP0
SINAMICS G120X Potencia asignada: 0,75 kW al 110% 60 s, 100% 240 s sin filtrar 200-240 V 3 AC + 10/– 20 %, 47-63 Hz Temperatura ambiente –20 a +45 °C Tamaño: FSA Grado de protección IP20/UL open Type pintura 3C2 Con Intelligent Operator Panel Sin ampliación de IO Bus de campo integrado: PROFIBUS-DP |
||
1,1 kW | |||
![]() |
6SL3220-3YC12-0UB0
SINAMICS G120X Potencia asignada: 1,1 kW al 110% 60 s, 100% 240 s sin filtrar 200-240 V 3 AC + 10/– 20 %, 47-63 Hz Temperatura ambiente –20 a +45 °C Tamaño: FSA Grado de protección IP20/UL open Type pintura 3C2 Con Intelligent Operator Panel Sin ampliación de IO Bus de campo integrado: MODBUS RTU, BACnet MS/TP,USS |
||
![]() |
6SL3220-3YC12-0UP0
SINAMICS G120X Potencia asignada: 1,1 kW al 110% 60 s, 100% 240 s sin filtrar 200-240 V 3 AC + 10/– 20 %, 47-63 Hz Temperatura ambiente –20 a +45 °C Tamaño: FSA Grado de protección IP20/UL open Type pintura 3C2 Con Intelligent Operator Panel Sin ampliación de IO Bus de campo integrado: PROFIBUS-DP |
||
1,5 kW | |||
![]() |
6SL3220-3YC14-0UB0
SINAMICS G120X Potencia asignada: 1,5 kW al 110% 60 s, 100% 240 s sin filtrar 200-240 V 3 AC + 10/– 20 %, 47-63 Hz Temperatura ambiente –20 a +45 °C Tamaño: FSA Grado de protección IP20/UL open Type pintura 3C2 Con Intelligent Operator Panel Sin ampliación de IO Bus de campo integrado: MODBUS RTU, BACnet MS/TP,USS |
||
![]() |
6SL3220-3YC14-0UP0
INAMICS G120X Potencia asignada: 1,5 kW al 110% 60 s, 100% 240 s sin filtrar 200-240 V 3 AC + 10/– 20 %, 47-63 Hz Temperatura ambiente –20 a +45 °C Tamaño: FSA Grado de protección IP20/UL open Type pintura 3C2 Con Intelligent Operator Panel Sin ampliación de IO Bus de campo integrado: PROFIBUS-DP |
||
2,2 kW | |||
![]() |
6SL3220-3YC16-0UB0
SINAMICS G120X Potencia asignada: 2,2 kW al 110% 60 s, 100% 240 s sin filtrar 200-240 V 3 AC + 10/– 20 %, 47-63 Hz Temperatura ambiente –20 a +45 °C Tamaño: FSB Grado de protección IP20/UL open Type pintura 3C2 Con Intelligent Operator Panel Sin ampliación de IO Bus de campo integrado: MODBUS RTU, BACnet MS/TP,USS |
||
![]() |
6SL3220-3YC16-0UP0
SINAMICS G120X Potencia asignada: 2,2 kW al 110% 60 s, 100% 240 s sin filtrar 200-240 V 3 AC + 10/– 20 %, 47-63 Hz Temperatura ambiente –20 a +45 °C Tamaño: FSB Grado de protección IP20/UL open Type pintura 3C2 Con Intelligent Operator Panel Sin ampliación de IO Bus de campo integrado: PROFIBUS-DP |
||
2,2 kW | |||
![]() |
6SL3220-3YC18-0UB0
SINAMICS G120X Potencia asignada: 3 kW al 110% 60 s, 100% 240 s sin filtrar 200-240 V 3 AC + 10/– 20 %, 47-63 Hz Temperatura ambiente –20 a +45 °C Tamaño: FSB Grado de protección IP20/UL open Type pintura 3C2 Con Intelligent Operator Panel Sin ampliación de IO Bus de campo integrado: MODBUS RTU, BACnet MS/TP,USS |
||
![]() |
6SL3220-3YC18-0UP0
SINAMICS G120X Potencia asignada: 3 kW al 110% 60 s, 100% 240 s sin filtrar 200-240 V 3 AC + 10/– 20 %, 47-63 Hz Temperatura ambiente –20 a +45 °C Tamaño: FSB Grado de protección IP20/UL open Type pintura 3C2 Con Intelligent Operator Panel Sin ampliación de IO Bus de campo integrado: PROFIBUS-DP |
||
4 kW | |||
![]() |
6SL3220-3YC20-0UB0
SINAMICS G120X rated power: 4 kW at 110% 60s, 100% 240s unfiltered 200-240V3AC+10/-20% 47-63Hz ambient temperature -20 to +45 °C frame size: FSB degree of protection IP20 / UL open type painting 3C2 with Intelligent Operator Panel without IO expansion fieldbus integrated: MODBUS RTU, BACnet MS/TP,USS. SIEMENS |
||
![]() |
6SL3220-3YC20-0UP0
SINAMICS G120X rated power: 4 kW at 110% 60s, 100% 240s unfiltered 200-240V3AC+10/-20% 47-63Hz ambient temperature -20 to +45 °C frame size: FSB degree of protection IP20 / UL open type painting 3C2 with Intelligent Operator Panel without IO expansion fieldbus integrated: PROFIBUS DP. SIEMENS |
||
7.5 kW | |||
![]() |
6SL3220-3YC24-0UB0
SINAMICS G120X rated power: 7.5 kW at 110% 60s, 100% 240s unfiltered 200-240V3AC+10/-20% 47-63Hz ambient temperature -20 to +45 °C frame size: FSC degree of protection IP20 / UL open type painting 3C2 with Intelligent Operator Panel without IO expansion fieldbus integrated: MODBUS RTU, BACnet MS/TP,USS. SIEMENS |
||
![]() |
6SL3220-3YC24-0UF0
SINAMICS G120X rated power: 7.5 kW at 110% 60s, 100% 240s unfiltered 200-240V3AC+10/-20% 47-63Hz ambient temperature -20 to +45 °C frame size: FSC degree of protection IP20 / UL open type painting 3C2 with Intelligent Operator Panel without IO expansion fieldbus integrated: PROFINET PN, Ethernet IP. SIEMENS |
||
![]() |
6SL3220-3YC24-0UP0
SINAMICS G120X rated power: 7.5 kW at 110% 60s, 100% 240s unfiltered 200-240V3AC+10/-20% 47-63Hz ambient temperature -20 to +45 °C frame size: FSC degree of protection IP20 / UL open type painting 3C2 with Intelligent Operator Panel without IO expansion fieldbus integrated: PROFIBUS DP. SIEMENS |
||
18.5 kW | |||
![]() |
6SL3220-3YC30-0UB0
SINAMICS G120X rated power: 18.5 kW at 110% 60s, 100% 240s unfiltered 200-240V3AC+10/-20% 47-63Hz ambient temperature -20 to +45 °C frame size: FSD degree of protection IP20 / UL open type painting 3C2 with Intelligent Operator Panel without IO expansion fieldbus integrated: MODBUS RTU, BACnet MS/TP,USS. SIEMENS |
||
![]() |
6SL3220-3YC30-0UF0
SINAMICS G120X rated power: 18.5 kW at 110% 60s, 100% 240s unfiltered 200-240V3AC+10/-20% 47-63Hz ambient temperature -20 to +45 °C frame size: FSD degree of protection IP20 / UL open type painting 3C2 with Intelligent Operator Panel without IO expansion fieldbus integrated: PROFINET PN, Ethernet IP. SIEMENS |
||
![]() |
6SL3220-3YC30-0UP0
SINAMICS G120X rated power: 18.5 kW at 110% 60s, 100% 240s unfiltered 200-240V3AC+10/-20% 47-63Hz ambient temperature -20 to +45 °C frame size: FSD degree of protection IP20 / UL open type painting 3C2 with Intelligent Operator Panel without IO expansion fieldbus integrated: PROFIBUS DP. SIEMENS |
||
30 kW | |||
![]() |
6SL3220-3YC34-0UB0
SINAMICS G120X rated power: 30 kW at 110% 60s, 100% 240s unfiltered 200-240V3AC+10/-20% 47-63Hz ambient temperature -20 to +45 °C frame size: FSE degree of protection IP20 / UL open type painting 3C2 with Intelligent Operator Panel without IO expansion fieldbus integrated: MODBUS RTU, BACnet MS/TP,USS. SIEMENS |
||
![]() |
6SL3220-3YC34-0UF0
SINAMICS G120X rated power: 30 kW at 110% 60s, 100% 240s unfiltered 200-240V3AC+10/-20% 47-63Hz ambient temperature -20 to +45 °C frame size: FSE degree of protection IP20 / UL open type painting 3C2 with Intelligent Operator Panel without IO expansion fieldbus integrated: PROFINET PN, Ethernet IP. SIEMENS |
||
![]() |
6SL3220-3YC34-0UP0
SINAMICS G120X rated power: 30 kW at 110% 60s, 100% 240s unfiltered 200-240V3AC+10/-20% 47-63Hz ambient temperature -20 to +45 °C frame size: FSE degree of protection IP20 / UL open type painting 3C2 with Intelligent Operator Panel without IO expansion fieldbus integrated: PROFIBUS DP. SIEMENS |
||
55 kW | |||
![]() |
6SL3220-3YC40-0UB0
SINAMICS G120X rated power: 55 kW at 110% 60s, 100% 240s unfiltered 200-240V3AC+10/-20% 47-63Hz ambient temperature -20 to +45 °C frame size: FSF degree of protection IP20 / UL open type painting 3C2 with Intelligent Operator Panel without IO expansion fieldbus integrated: MODBUS RTU, BACnet MS/TP,USS. SIEMENS |
||
![]() |
6SL3220-3YC40-0UF0
SINAMICS G120X rated power: 55 kW at 110% 60s, 100% 240s unfiltered 200-240V3AC+10/-20% 47-63Hz ambient temperature -20 to +45 °C frame size: FSF degree of protection IP20 / UL open type painting 3C2 with Intelligent Operator Panel without IO expansion fieldbus integrated: PROFINET PN, Ethernet IP. SIEMENS |
||
![]() |
6SL3220-3YC40-0UP0
SINAMICS G120X rated power: 55 kW at 110% 60s, 100% 240s unfiltered 200-240V3AC+10/-20% 47-63Hz ambient temperature -20 to +45 °C frame size: FSF degree of protection IP20 / UL open type painting 3C2 with Intelligent Operator Panel without IO expansion fieldbus integrated: PROFIBUS DP. SIEMENS |